Key Benefits and Features of Inertsil ODS-3 - Part of the Advanced Inertsil 3-Series of Phases
 
   Virtually perfect peak shape for most bases and acids - Perhaps the MOST BASE-DEACTIVATED column on the market.
   Predictable selectivity with very low operating pressure making this ideal for fast/LC,  UPLCTM, and LC/MS
   Exceptional physical and chemical durability provides long column life
   Vast database of chromatographic applications available to assist in method development
     Click here for Inertsil ODS-3 ordering information 
 GL Sciences’ Inertsil columns offer everything you need for your critical separations in all phases of drug development, and something less. Inertsil’s uniquely modified silicas and meticulously engineered column hardware allow our columns to operate at significantly lower back pressures than competitive columns, without sacrificing efficiency. Inertsil’s wide pH compatibility and excellent stability at elevated temperatures make it the ideal choice for your chromatography needs, whether you are using a traditional HPLC system or the latest rapid gradient LC/MS system with precise temperature control.

For example, examine the chromatograms shown at far right, with separation of 5 peptides in under 1 minute on both a "standard" HP1050 LC and a Waters UPLCTM.

In the chromatogram below, an Inertsil ODS-3, 3 µm, 50 x 2.1mm column was used to analyze 4 basic compounds (antidepressants), in under 0.5 minutes (click on image to enlarge).

Inertsil is available in a wide range of bonded phases, including ODS-3, ODS-Sprint for reduced retention of non-polar compounds, C8-3, Phenyl-3, ODS-EP containing an embedded polar group for increased retention of polar compounds, CN-3, HILIC, NH2, Diol, and a Polymerically bonded ODS-P phase with unique selectivity for planar compounds, uniquely designed for analysis of 16 priority PAHs in environmental samples but has also found to be useful for pharmaceutical analysis of planar compounds. Visit www.inertsil.com to peruse a huge selection of applications data to assist you in finding the best column for your next project. Ordering information for our most popular phases is found on the back cover of this brochure. The many tens of other configurations from capillary to prep are shown at inertsil.com.

The Inertsil 3-series represents a major advance in performance over the original Inertsil 2-Series. Inertsil 3-Series phases, including ODS-3, ODS-3V, ODS-SPRINT ODS-P, ODS-EP, C8-3, Ph-3, CN-3, NH2, Diol, and SIL-100Å, are based on a purer, higher surface area silica which is specially manufactured to provide maximum bonded phase coverage.  The result is a series of columns which provide excellent peak shapes using simple eluents while operating at low pressure.

Inertsil ODS-3, along with most of the other Inertsil 3-series phases, are available in 3, 5, and 8 micron particle sizes in column configurations ranging from capillary to 50mm ID preparative sizes.

GL Sciences has compiled a vast collection of chromatographic applications data on ODS-3 and their other phases which can assist you in method development.  These can be accessed under the "chromatograms" link on the main menu bar above, by searching for a particular compound using our "search" link above, or by clicking here.
 
By choosing Inertsil ODS-3, you can be assured  that you are using one of the most trusted, popular, and enduring HPLC columns in the history of HPLC.

  Click here for Inertsil ODS-3 ordering information

  Click here to find a local authorized Inertsil Dealer

 

Above - FAST Peptide Separation (Gly-Tyr, Val-Tyr-Val, angiotensin II, Leu enkephalin, Met enkephalin, in order of elution) chromatograms at velocities of 7 mm/s (5 mL/min) using an ordinary HPLC (top) with 4.6 x 50 mm column and 14 mm/s  (2 mL/min) using a UPLCTM with 2.1 x 50 mm column (bottom).  In both cases, a 5-35% ACN linear gradient with 0.2% HOAc buffer and InertsilTM ODS3 – 3 µm stationary phase were used.



Figure 1 - Tanaka Test for Selectivity
Column:
Inertsil 3 Series 150 x 4.6mm
Order No. for Inertsil ODS-3:
1015L150W046
Eluent:
MeOH:Water 80:20 Flow: 1.0 ml/min Temp: 40°C Detection: UV @ 254nm  Sample: 1. caffeine, 2. phenol, 3. n-Butylbenzene, 4. n-amylbenzene, 5. o-terphenyl, 6. triphenylene
Notes: 
The Tanaka test is one of several industry-wide standard tests which illustrate selectivity differences between bonded phases. The wide range of Inertsil Series-3 phases show vast selectivity differences in Tanaka test, allowing a wide array of compounds to be separated. (Click on image below for larger view)

 

Click on image for larger view - FIGURE 2

Figure 2 - Difficult Separation of Highly Basic Compounds
Column:
Inertsil ODS-3, 150 x 4.6mm
Order No.: 1015L150W046
Eluent: MeCN:20mM KH2PO4 (pH 7.0) 70:30
Flow: 1.0 ml/min  Temp: 40°C  Detection: UV @ 254nm
Sample: 1. propranolol ( 56 ug/ml) , 2. nortriptyline (11 ug/ml), 3. amitriptyline (11 ug/ml) 4. trimipramine (11 ug/ml)
Notes: Chromatogram shows nice separation and very nice peak shape for these compounds which often show unacceptable peak tailing on other columns

 
 
Particle
Size(s)
Particle
Shape
Surface
Area 
Pore
Size 
Pore
Volume 
Silica
Purity 
Bonded
Phase 
End-
Capping
Carbon
Load
pH
Range*
3, 5, 8 µmSpherical450 m2/g100Å1.05 mL/g99.999%Octadecyl
Groups
Yes15%2 - 7.5
* Inertsil phases are known to provide excellent results and long column life at pH levels of 9-10. However, optimum column life may be achieved  at a pH between 2 and 7.5.