Key Benefits and Features of Inertsil Ph-3 - Part of the Advanced Inertsil 3-Series of Phases
   Virtually perfect peak shape for most bases and acids
   Unique selectivity
   Exceptional physical and chemical durability provides long column life
   Vast database of chromatographic applications available to assist in method development
   Very low operating back pressure
      Click here for Inertsil Ph-3 ordering information 
 Inertsil Ph-3 provides pure reverse phase characteristics that are critical to resolving highly polar compounds like acidic and basic pharmaceuticals.  The near perfect phenyl phase  coverage on this material results in symmetric, narrow peaks for even the most polar compounds while using simple eluents like aqueous MeCN or MeOH.  The need for ion-pair and competing-amine eluent modifiers that are necessary with many other reverse phase columns is eliminated on Inertsil 3-series phases.

The Inertsil 3-series represents a major advance in performance over the original Inertsil 2-Series. Inertsil 3-Series phases, including ODS-3, ODS-3V, ODS-P, ODS-EP, C8-3, Ph-3, ODS-SPRINTCN-3, NH2, Diol, and SIL-100Å, are based on a purer, higher surface area silica which is specially manufactured to provide maximum bonded phase coverage.  The result is a series of columns which provide excellent peak shapes using simple eluents while operating at low pressure.
 
Inertsil Ph-3, along with most of the other Inertsil 3-series phases, are available in 3, 5, and 8 micron particle sizes in column configurations ranging from capillary to 50mm ID preparative sizes.

GL Sciences has compiled a vast collection of chromatographic applications data on Ph-3 and their other phases which can assist you in method development.  These can be accessed under the "chromatograms" link on the main menu bar above, by searching for a particular compound using our "search" link above, or by clicking here.
 
By choosing Inertsil Ph-3, you can be assured  that you are using one of the most trusted, popular, and enduring HPLC columns in the history of HPLC.

  Click here for Inertsil Ph-3 ordering information
  Click here to find a local authorized Inertsil Dealer

  
Figure 1 - Tanaka Test for Selectivity
Column:
Inertsil 3 Series 150 x 4.6mm
Order No. for Inertsil Ph-3:
1042L150W046
Eluent:
MeOH:Water 80:20 Flow: 1.0 ml/min Temp: 40°C Detection: UV @ 254nm  Sample: 1. caffeine, 2. phenol, 3. n-Butylbenzene, 4. n-amylbenzene, 5. o-terphenyl, 6. triphenylene
Notes: 
The Tanaka test is one of several industry-wide standard tests which illustrate selectivity differences between bonded phases. The wide range of Inertsil Series-3 phases show vast selectivity differences in Tanaka test, allowing a wide array of compounds to be separated.

Inertsil Ph-3, along with most of the other Inertsil 3-series phases, are available in 3, 5, and 8 micron particle sizes in column configurations ranging from capillary to 50mm ID preparative sizes.

 
Particle
Size(s)
Particle
Shape
Surface
Area 
Pore
Size 
Pore
Volume 
Silica
Purity 
Bonded
Phase 
End-
Capping
Carbon
Load
pH
Range*
3, 5, 8 µmSpherical450 m2/g100Å1.05 mL/g99.999%Phenyl
Groups
No9.5%2 - 7.5

* Inertsil phases are known to provide excellent results and long column life at pH levels of 9 or 10. 
However, optimum column life will likely be achieved by operating at a pH of between 2 and 7.5.